GEYSERWISE MAX CONTROLLER IOT

SKU 66-CN-T18

R2,336.00

The GeyserWise Max Controller is designed for 12V and 220V solar water heating systems. It features a clear display for temperature, time, and mode, with adjustable settings (30–75°C) and daily programmable timers. Safety features include an electronic thermostat, thermal cut-out at 90°C, and error alerts (E1-E9). Optimize your heating efficiently!

Categories: ,

Description

Product Overview

The GeyserWise Max Controller is an advanced management system for 12V and 220V solar water heating setups. This versatile device operates as both a geyser timer and a controller for thermosyphon systems, optimizing water heating performance and boosting energy efficiency. It’s designed for users who want precise control over their water heating needs while minimizing energy consumption.

Key Features

User-Friendly Display

The GeyserWise Max Controller features a clear, easy-to-read display. It shows essential details such as water temperature, current time, day, heating mode, and any detected faults. This ensures that users have all the necessary information at a glance. The system supports both automatic and manual heating modes, making it adaptable to different preferences and needs.

Adjustable Temperature Settings

The controller allows users to set water temperatures between 30°C and 75°C, with a default setting of 55°C for optimal comfort. This range ensures that you can adjust the temperature according to your specific needs, whether it’s for a warm shower or a high-temperature cleaning cycle.

Customizable Programming

With four programmable time settings available each day, the GeyserWise Max lets users schedule heating periods to match their routines. This feature is especially useful for reducing energy use during off-peak hours or when hot water is not required.

Safety First

The GeyserWise Max is equipped with multiple safety features to ensure reliable operation. It includes an electronic thermostat and a mechanical thermal cut-out set at 90°C, which prevent overheating. Additionally, if the water temperature exceeds 84°C, a high-temperature warning is triggered, alerting users to potential issues.

Technical Specifications

  • Operating Voltage: 230VAC / 50Hz
  • Main Relay Contact Rating: 30A (Max 4KW)
  • Secondary Relay Rating: 5A for pump and solenoid
  • Temperature Display Range: 0°C to 99°C
  • Temperature Settings: 30°C to 75°C
  • High-Temperature Warning: Above 84°C

Temperature Probes:

  • Geyser Probe Range: -30°C to +130°C
  • Collector Probe Range: -30°C to +260°C

Additional Safety Features

The GeyserWise Max includes dry heat detection, earth leakage protection, and collector antifreeze protection, which activates at 5°C. These features protect the system from damage and ensure long-term reliability, even in challenging conditions.

Conclusion

In summary, the GeyserWise Max Controller is a comprehensive solution for managing solar water heating systems. Its combination of user-friendly features, customizable settings, and robust safety measures makes it an ideal choice for homeowners looking to optimize energy use and maintain consistent hot water availability.